Go to the NASA Homepage
 
Search >
Click to Search
Human Systems Integration Division homepageHuman Systems Integration Division homepage Organization pageOrganization page Technical Areas pageTechnical Areas page Outreach and Publications pageOutreach and Publications page Contact pageContact page
Human Systems Integration Division Homepage
Outreach & Publications Sidebar Header
Go to the Outreach & Publications pageGo to the Outreach & Publications page
Go to Awards pageGo to Awards page
Go to News pageGo to News page
Go to Factsheets pageGo to Factsheets page
Go to Multimedia pageGo to Multimedia page
Go to Human Factors 101 pageGo to Human Factors 101 page
What is Human System Integration? Website
Publication Header
Validation of a touchscreen psychomotor vigilance task. Accident Analysis & Prevention  (2017)
Abstract Header
Objective
The purpose of this study was to compare a psychomotor vigilance task developed for use on touchscreen devices with the original PVT-192 in conditions of acute sleep loss and circadian desynchronization.

Background
The Psychomotor Vigilance Task (PVT) is considered the gold standard fatigue detection test and is used frequently in fatigue research. With the rapid development of new technologies it is essential to develop a PVT available on different platforms such as touchscreen devices. The advantage of such PVT is that it can be implemented on small devices and can be easily used in field studies.

Methods
Ten participants completed a 5-min PVT (NASA-PVT) on a touchscreen device and a 5-min PVT on the original PVT-192. On the day of the experiment, participants arrived in the lab approximately two hours after their habitual wake time. Participants completed a constant routine protocol under dim lighting, while maintaining a constant posture. The 5-min PVT-192 and NASA-PVT were taken every two hours for at least 24 h.

Results
The NASA-PVT and PVT-192 were sensitive to extended wakefulness in the same manner. The reaction times were slower and the lapses were higher as time progressed on both NASA-PVT and PVT-192 (p < 0.001). Overall, there was a sharp decline in performance after 16 h of being awake which coincided with the time the participants were usually going to bed and the worst performance occurred after 24 h of wakefulness for both PVTs (p < 0.001).

Conclusions
Overall, our data suggest that the NASA-PVT is a valid tool for assessing fatigue in field studies.
Private Investigators Header
Authors Header
Groups Header
Keywords Header
Accident, Analysis, Prevention, psychomotor, PVT, task, touchscreen, Validation, vigilance
References Header
Accid Anal Prev. 2017. https://doi.org/10.1016/j.aap.2017.11.041
Go to the First Gov Homepage
Go to the NASA - National Aeronautics and Space Administration Homepage
Curator: Phil So
NASA Official: Jessica Nowinski
Last Updated: August 15, 2019